BH GSO ASTM E1662:2023 Scope
1.1 This classification covers pairs of scales for classifying
an aspect of the serviceability of an office facility, that is, the
capability of an office facility to meet certain possible requirements for suitable sound and visual conditions.
1.2 Within that aspect of serviceability, each pair of scales,
shown in Figs. 1-6, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see
Figs. 1-6) summarizes one level of serviceability on that topic,
which occupants might require. The matching entry in the
Facility Rating Scale (see Figs. 1-6) is a translation of the
requirement into a description of certain features of a facility
which, taken in combination, indicate that the facility is likely
to meet that level of required serviceability.
1.3 The entries in the Facility Rating Scale (see Figs. 1-6)
are indicative and not comprehensive. They are for quick
scanning to estimate approximately, quickly, and economically,
how well an office facility is likely to meet the needs of one or
another type of occupant group over time. The entries are not
for measuring, knowing, or evaluating how an office facility is
performing.
1.4 This classification can be used to estimate the level of
serviceability of an existing facility. It can also be used to
estimate the serviceability of a facility that has been planned
but not yet built, such as one for which single-line drawings
and outline specifications have been prepared.
1.5 This classification indicates what would cause a facility
to be rated at a certain level of serviceability but does not state
how to conduct a serviceability rating nor how to assign a
serviceability score. That information is found in Practice
E1334. The scales in this classification are complimentary to
and compatible with Practice E1334. Each requires the other
Best Sellers From Construction and Building Sector
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 2084:2010
Gulf Standard
Design and application of speed control humps
GSO 1421:2002
Gulf Technical Regulation
Hollow blocks made from clay for walls
Recently Published from Construction and Building Sector
GSO ASTM C990:2024
ASTM C990:09(2019)
Gulf Standard
Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants
GSO ISO 12241:2024
ISO 12241:2022
Gulf Standard
Thermal insulation for building equipment and industrial installations — Calculation rules
GSO EN 772-11:2024
EN 772-11:2011
Gulf Standard
Methods of test for masonry units - Part 11: Determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay masonry units
GSO ASTM C778:2024
ASTM C778:21
Gulf Standard
Standard Specification for Standard Sand